應(yīng)用領(lǐng)域
Prosonic Flow B 200 可在過程條件波動的情況下對濕沼氣和消化池氣體進行精確、可靠的測量。此外,Prosonic Flow B 200 還能夠提供實時甲烷含量分析,這一獨有的特性不但能夠讓用戶對氣體的流量進行連續(xù)不斷的測量,而且還能夠?qū)怏w的質(zhì)量進行持續(xù)的監(jiān)測。此外,心跳技術(shù)能夠保證有效的過程控制和能量平衡,并始終確保合規(guī)性與過程安全性。
優(yōu)勢
產(chǎn)品規(guī)格參數(shù)
測量原理
超聲波流量測量
產(chǎn)品標(biāo)題
The device for accurate, reliable biogas measurement with loop-powered technology.
Inline flowmeter designed for measurement of wet biogas and digester gas under fluctuating process conditions.
傳感器特點
Optimized for low pressure gas – specialized sensor design. No additional pressure loss – full-bore design. Process transparency – diagnostic capability.
Multivariable device: flow, temperature and methane. Medium temperature: 0 to 80 °C (32 to 176 °F). Process pressure: 0.7 to 11 bar a (10.2 to 159 psi a).
變送器特點
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals.
公稱口徑范圍
單聲路型:DN 50 (2")、DN 80 (3")
雙聲路型:DN 100...200 (4...8")
接液部件材質(zhì)
傳感器:1.4404/1.4435 (316L)
超聲波變送器:HNBR
溫度傳感器(可選):AFM 34
測量變量
體積流量、校正體積流量、校正甲烷體積流量、能量流、甲烷濃度、比熱值、溫度
最大測量誤差
體積流量(標(biāo)準(zhǔn)):
‐ ±1.5 % o.r.:3...30 m/s (9.84...98.4 ft/s)
‐ ±3 % o.r.:1...3 m/s (3.28...9.84 ft/s)
體積流量(可選):
‐ ±0.1 % o.f.s.:0.3...1 m/s (0.98...3.28 ft/s)
‐ ±1.5 % o.r.:1...30 m/s (3.28...98.4 ft/s)
測量范圍
標(biāo)準(zhǔn):1...30 m/s (3.28...98.4 ft/s)
可選:0.3...30 m/s (0.98...98.4 ft/s)
最大過程壓力
11 bar a (159 psi a)
介質(zhì)溫度范圍
0...+80 °C (+32...+176 °F)
環(huán)境溫度范圍
碳鋼法蘭:–10...+60 °C (+14...+140 °F)
不銹鋼法蘭:–40...+60 °C (–40...+140 °F)
變送器外殼材質(zhì)
鋁合金AlSi10Mg涂層:1.4404 (316L)
防護等級
IP66/67,Type 4X
顯示/操作
四行背光顯示,觸摸鍵操作
(外部操作)
通過現(xiàn)場顯示單元和調(diào)試軟件設(shè)置
輸出
4...20 mA HART(無源)
4...20 mA(無源)
脈沖/頻率/開關(guān)量輸出(無源)
輸入
4...20 mA電流輸入(無源)
數(shù)字通信
HART
電源
12...35 VDC(4...20 mA HART,帶/不帶脈沖/頻率/開關(guān)量輸出)
12...30 VDC(4...20 mA HART,4...20 mA)
12...35 VDC(4...20 mA HART,脈沖/頻率/開關(guān)量輸出,4...20 mA輸出)
9...32 VDC(PROFIBUS PA,脈沖/頻率/開關(guān)量輸出)
防爆認(rèn)證
ATEX、IECEx、cCSAus、NEPSI、INMETRO、TIIS
計量認(rèn)證和證書
在認(rèn)證標(biāo)定裝置上標(biāo)定(符合ISO/IEC 17025標(biāo)準(zhǔn))
壓力認(rèn)證和證書
PED
材料證書
3.1材料證書(接液部件)